| Power |
|---|
| Output voltage regulation | 1% |
| Output power | 1000 W |
| Input operation voltage (min) | 110 V |
| Input operation voltage (max) | 300 V |
| Output operation voltage (min) | 208 V |
| Output operation voltage (max) | 240 V |
| Emergency Power Off (EPO) | Yes |
| Power factor | 0.99 |
| Crest factor | 3:1 |
| Output power capacity | 1 kVA |
| Total Harmonic Distortion (THD) (linear load) | 2% |
| Total Harmonic Distortion (THD) (non-linear load) | 4% |
| Performance |
|---|
| Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
| UPS topology | Double-conversion (Online) |
| Waveform | Sine |
| Number of input phases | 1 |
| Response time | 4 ms |
| Surge protection | Yes |
| Noise level | 50 dB |
| Audible alarm(s) | Yes |
| Features |
|---|
| Output frequency | 46/64 Hz |
| Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
| UPS topology | Double-conversion (Online) |
| Waveform | Sine |
| Output voltage regulation | 1% |
| Number of input phases | 1 |
| Response time | 4 ms |
| Output power | 1000 W |
| Input operation voltage (min) | 110 V |
| Input operation voltage (max) | 300 V |
| Output operation voltage (min) | 208 V |
| Output operation voltage (max) | 240 V |
| Surge protection | Yes |
| Emergency Power Off (EPO) | Yes |
| Power factor | 0.99 |
| Noise level | 50 dB |
| Crest factor | 3:1 |
| Audible alarm(s) | Yes |
| Output power capacity | 1 kVA |
| Total Harmonic Distortion (THD) (linear load) | 2% |
| Total Harmonic Distortion (THD) (non-linear load) | 4% |
| Input frequency | 40/70 Hz |
| Ports & interfaces |
|---|
| Emergency Power Off (EPO) connector | Yes |
| USB port | Yes |
| Serial interface | Yes |
| Serial interface type | RS-232 |
| AC outlet types | C13 coupler |
| USB 2.0 ports quantity | 1 |
| USB port type | USB Type-B |
| Battery |
|---|
| Battery voltage | 12 V |
| Battery capacity | 9 Ah |
| Number of battery cells | 2 |
| Battery recharge time | 3 h |
| Typical backup time at full load | 33 min |
| Hot-swap battery | Yes |
| Design |
|---|
| Form factor | Rackmount/Tower |
| Product colour | Black |
| Cooling type | Active |
| Certification | EMC EN62040-2 C2 |
| Built-in fan | Yes |
| Control type | Buttons |
| Display type | LCD |
| Operational conditions |
|---|
| Operating temperature (T-T) | 0 - 40 °C |
| Operating relative humidity (H-H) | 20 - 90% |
| Technical details |
|---|
| Output frequency | 46/64 Hz |
| Sustainability compliance | Yes |
| Harmonized System (HS) code | 85078000 |
| Compliance certificates | CE |
| Packaging data |
|---|
| Packaging content | UPS, user manual, software CD, C14-C13 cable, USB cable, tower stands, mounting ears & screws |
| Cooling |
|---|
| Cooling type | Active |
| Built-in fan | Yes |
| Weight & dimensions |
|---|
| Weight | 11.6 kg |
| Width | 438 mm |
| Height | 88 mm |
| Depth | 410 mm |
| Logistics data |
|---|
| Harmonized System (HS) code | 85078000 |
| Certificates |
|---|
| Certification | EMC EN62040-2 C2 |
| Other features |
|---|
| Packaging content | UPS, user manual, software CD, C14-C13 cable, USB cable, tower stands, mounting ears & screws |
| Packaging content |
|---|